Choose a language.

Masterclock.com can now be viewed in other languages thanks to Google Translator. The translation is computer generated and at times may be less than perfect. We hope that you appreciate that this is an experiment to determine the best way to reach our customers globally and that the translation at times may not make sense.

...Masterclock Generators: MCR1000  MCR Series Video

Masterclock Generator MCR1000 Time Server and more

Masterclock Generator MCR1000 Time Server and more Masterclock Generator MCR1000 Time Server from Rear Masterclock Generator MCR100 Time Server Board

This is our modular solution:

an NTP generator with bays for 3 modules. You can plug in a GPS reference, High Stability Oscillator reference, Time Code Reader or Time Code Generator.

pdfData Sheet
pdfUser Manual
Catalogs

OVERVIEW


Masterclock's Master Clock Reference system is a compact, precision time and frequency generator for a wide range of applications in the commercial, industrial, military and laboratory environment.

One compact unit can generate and read NTP, time code, high stability oscillator, and 10 MHz sinewave all locked to the Atomic Clocks in the GPS satellites.

With specifications that are equal or better than almost any other similar product the MCR is up to 60% less expensive than competitive units.

The MCR 1000 is available in multiple configurations to fit almost any need with configurable plug-in modules. Give our sales department a call and discover how easy it is to configure a system to fit your requirements.

APPLICATIONS


GPS Referenced
  • Time Code Generator
  • NTP Server
  • 10 MHz Sinewave
  • PPS
  • Scheduled relay closure

NTP Referenced
  • Time Code Generator
  • 10 MHz
  • PPS
  • Scheduled relay closure

Time Code Referenced
  • NTP
  • Time Code Generator
  • 10 MHz
  • PPS
  • Scheduled relay closure

High Stability Oscillator Referenced
  • NTP
  • Time Code Generator
  • 10 MHz
  • PPS
  • Scheduled relay closure

NMEA 0183 Referenced
  • NTP
  • Time Code Generator
  • Scheduled relay closure

Programmable Relay

Display Time / Date - Day of Year

BASIC


Reference Sources
  • NTP client via 10/100 MB Ethernet
  • High stability TCXO oscillator
    +/- 1 Min / year
  • Manual time set

Outputs
  • PC time set via USB serial
  • Programmable relay closure

Setup & Configuration Software
  • WinDiscovery network
  • Telnet software for UNIX/LINUX
  • MCRSET Windows

Programmable Relay
  • Schedule 1 event per day
    relay closure
    with N/O relay contact,
    24V - AC/DC (250 ma max)

OPTIONAL


Reference Sources
  • GPS
  • Ultra stable oscillator +/- 250 ms
    (1/4 sec.) year
  • Time code basic
    - IRIG B and SMPTE / EBU
  • Time code advanced - IRIG A and E
  • NMEA 0183

Outputs
  • NTP - server via 10/100 MB Ethernet
  • Time code basic - IRIG B and SMPTE / EBU
  • Time code advanced - IRIG A and E
  • NMEA 0183 via RS232 & USB
  • Pulse output
  • 10MHz high stability sine wave
  • DB9 - Breakout Adapter

6 or 9 Digit Red LED Display

Basic Relay Scheduler
- Multiple events per day software
  • Up to 128 events per day

CONNECTORS

  • RJ45 Ethernet connection
  • DC input 2.1 mm jack
  • DB9 I/O
  • USB I/O
  • RS232 NMEA I/O
  • BNC-9 adapter supplied with time code options *
  • Antenna - SMA *
  • 10 MHz - SMA *
  • AUX - SMA *

* Optional

RELAY

  • N/O contacts, 24V AC/DC, 250 ma max rating

PHYSICAL

  • Size - 6.75 x 4.13 x 1.5 (inches) - 17.15 x 10.48 x 3.81 (cm)
  • Weight - 17.3 oz. - 490.5 g
  • Cover - pearl white aluminum
  • Front/rear panel - clear anodized aluminum

OPERATING TEMPERATURE AND HUMIDITY

  • Temperature: 0°C to +40°C (40 to 50°C ±1 min/year)
  • Humidity: Up to 90% (non-condensing at +25°C)

POWER

  • 12 VDC external wall mount supplied, UL & CE listed, 115/230, 50/60 Hz
  • Power Consumption < 10W
  • Supplied with US, Euro-plug, British or AUS/NZ - others optionally available

COMPLIANCE


WinDiscovery: NTD Windows® device discovery and control program.

Play Movie allows the playing of the longer video inside the other windiscovery video pdfScreen shots WinDiscovery Product Page

NTD telnet device control program... pdf Screen shots


  • Supports DHCP/BOOTP for automatic acquisition of network address, nameservers, and time server configuration.
  • NTP synchronization options: server, port, timeout, query/listen mode.
  • Configuration of networking parameters, time zone/daylight savings time.
  • WinDiscovery provides automatic discovery of NTP clocks attached to network without changing PC's networking configuration.
  • Configuration is saved to non-volatile memory to survive power loss.
  • Encrypted messages prevent tampering with clock configuration.

Included With Every Configuration:


  • MCR1000
  • Cat-5 Ethernet Cable
  • 12 VDC external wall mount supplied, UL & CE listed, 115/230, 50/60 Hz
  • Threaded locking plug for DC input
  • Instruction manual and NTD Network Device Discovery Program, both on CD


Shipping Information: package weights, sizes and codes