Masterclock.com can now be viewed in other languages thanks to Google Translator. The translation is computer generated and at times may be less than perfect. We hope that you appreciate that this is an experiment to determine the best way to reach our customers globally and that the translation at times may not make sense.

...Time Code Products : TCS100

TCS-100 Time Code Switcher
TCS-100 Time Code Switcher TCS-100 Time Code Switcher Rear View

The TCS100 is an automatic time code changeover unit designed to provide automatic or manual switching between two time code sources.


Wall-mount power supply included.

pdf Data Sheet
pdf User Manual
Catalogs
  • Accepts SMPTE / EBU or IRIG-B (modulated and unmodulated TC), automatically determines TC type and switches to the alternate source if TC is lost or if a problem is detected in the primary TC source.
  • Decodes both sources of incoming TC, compares availabity and quality of both sources to a third internal standard maintained within the changeover unit, and makes logical decisions concerning TC status for the purpose of automatic switchover.
  • Front panel switches allow manual selection of source A or B or automatic mode.
  • "Good" / "Fail" indication and selection status of each TC source and the changeover unit is shown with front panel LEDs.
  • An auxiliary A/B source can be switched along with the TC. This auxiliary switching is a relay contact and can be used to switch any low level control or signal source.
  • Internal alarms sound (can be disabled with jumpers) upon loss or failure of a source of TC or switcher unit. A relay contact closure is provided for an external alarm. Alarm can be reset from front panel.
  • Status and other system information is provided via a simplex (one way) RS-232, 9600 BAUD
  • Operates from 120/240 VAC, 50 - 60 Hz, with external wall-mounted UL/CSA approved power supply (supplied) or external 12 - 28 VDC source (not included).

CONNECTORS

  • Timecode inputs - isolated BNC - balanced
  • Time code output - isolated BNC - balanced
  • Balanced input & output connections are available via DB-9
  • Auxilary switching connections via DB-9
  • External alarm connections via DB-9
  • Input power is 12 - 28 VDC via - 2mm male power connector

OPERATING TEMPERATURE

  • Temperature: 0 to +60°C

PHYSICAL

  • Size - 4.2 x 1.5 x 5.5 (inches) - 10.6 x 3.8 x 14 (cm)
  • Weight - 16 oz - 454 g (approximate w/o ps)
  • Power supply (approximate) 12 oz - 340g
  • Cover - eggshell white aluminum
  • Front/rear panel - burnished aluminum

POWER

  • 12 VDC external wall mount supplied, UL & CE listed
  • 115/230, 50/60 Hz
  • Power consumption < 2 watts
  • Supplied with US, Euro-plug, British or AUS/NZ - others optionally available
 
  • TCS100
  • Wall-mount power supply
  • Instruction manual on CD